Microbial mitigation case study —

Microbial compliance: 95%+ first test pass rates across 250,000 sq ft

65→95% SOP compliance, estimated to documented
Microbial mitigationOperating, underperformingClient not named
Cured cannabis flower held in front of a water activity meter
The problem —

Where it started

In May 2023 Nevada tightened its Aspergillus action limits to under 10,000 CFU per gram. Facilities that had been passing by a small margin started failing. Each one already had a sanitation program, and several ran UV-C or ozone remediation. None could pass consistently on the first test.

The facilities ranged from 15,000 to more than 100,000 square feet of canopy. The symptom was the same in each one. The root causes were not.

The approach —

What we did

Every engagement started with a forensic assessment across four areas, then a ranked intervention plan with a cost and an expected result for each item.

  • Environment. VPD mapping by room and growth stage, dehumidification capacity, zoning and condensation risk. Canopy VPD often ran 0.3 to 0.5 kPa below setpoint at peak transpiration.
  • Irrigation. Biofilm testing along the lines. Every long run or recirculating system showed biofilm, and none had a chlorine dioxide program.
  • Post harvest. Water activity checks found flower staged for packaging at 0.68 to 0.79, above the ASTM D8197 threshold of 0.65. No facility owned a calibrated meter.
  • Materials and SOPs. Drywall with subsurface moisture in two older facilities, and room turn SOPs missing at least two of five phases everywhere.

The common fixes followed from those findings.

  • Supplemental dehumidification, rezoning and continuous VPD logging with alarms.
  • Chlorine dioxide injection at 0.5 to 2 ppm, with a 5 to 10 ppm shock flush between crops.
  • A calibrated water activity meter, dry rooms held at 55 to 62% RH and 60 to 70°F, and packaging triggered by a reading of 0.55 to 0.65.
  • Insulated metal wall panels, epoxy floors and open frame stainless benches where materials were the reservoir.
  • Five phase room turn SOPs with supervisor sign off.
The results —

What changed

  • 95%+ first test pass rates within two to four harvest cycles of full implementation.
  • Most facilities that did everything on the plan reached consistent compliance in two cycles.
  • SOP compliance rose from an estimated 60 to 70% to a documented 95%+.
  • No facility in the cohort relied on post harvest remediation afterward.

Figures are client reported.

What did not go to plan

Facilities that deferred wall and floor retrofits for capital reasons improved, but took extra cycles to hold 95%.

Related equipment

This scope covered dehumidification, environmental monitoring, irrigation treatment, dry room control and room materials. Lines Urth & Fyre specifies and sources for this kind of work include Anden and Quest dehumidifiers, Urban Farms HVAC, Breeza Industrial fans, MicroCool fogging, Saturn Supply Co. irrigation and Next G3N benching. The Cannabis HVAC Design Guide covers dehumidification sizing and VPD targets.

The full method is in the long form write up. If your facility is failing tests, read about microbial and pathogen mitigation or request a facility assessment.