Cultivation Education7

Gavita LED Lineup: RS 2400e, 1900e, CT 2000e

Gavita LED lineup compared: RS 2400e, RS 1900e and CT 2000e watts, µmol/s, voltages, EL3 controller fit, heat load per fixture and which room each suits.

Cured flower held beside a water activity analyzer
Cured flower held beside a water activity analyzer

The current Gavita LED toplights are the Pro RS 2400e at 2,400 µmol/s from 800 watts, the six bar RS 1900e at about 1,900 µmol/s from 650 watts, and the CT 2000e compact toplight for HPS style layouts. Pick on your room's voltage and controller first. Then pick on how much light the canopy needs.

Which Gavita LED fixtures are current?

Gavita's current LED range is three toplights, an under canopy fixture, a propagation bar and the EL3 controller. Two older fixtures, the Pro 1700e and CT 1930e, still turn up in used rooms and matter for anyone expanding an existing facility.

  • Gavita Pro RS 2400e LED: 2,400 µmol/s at 3.0 µmol/J, 800 watts, 120 to 277 volts, 6.67 amps at 120 volts and 2.89 amps at 277 volts, 35.3 lb, IP66, rated to 40°C ambient. A 208 to 480 volt version is also offered.
  • Gavita RS 1900e LED: six bars, 650 watts, 208 to 480 volts, 3.12 amps at 208 volts and 1.35 amps at 480 volts, 27.5 lb, IP66. The sell sheet describes it at 1,900 µmol/s and 3.0 µmol/J and its dimming table measures 1,952 µmol/s at full output.
  • Gavita CT 2000e LED: the newest Compact Toplight, a 208 to 480 volt fixture with a broad white spectrum.
  • Gavita Under Canopy 150W LED: a dual sided fixture that adds 450 µmol/s below the canopy.
  • Gavita Clone Bar LED: a 9000K bar for rooting clones and seedlings on shelving.
  • Earlier models: the Pro 1700e at 1,700 µmol/s from 645 watts, and the CT 1930e at 780 watts, which Hawthorne sold as a one to one HPS replacement.

Both RS fixtures share a 44.8 by 43.25 inch frame, a Wieland RST 16i5 power inlet, ETL listing and conformance to UL 8800. Hawthorne announced the RS 2400e on March 2, 2023, assembled in Temecula, California, with a 5 year limited warranty. Gavita's sell sheets tie that warranty to purchase from an authorized Hawthorne dealer.

What voltage does each Gavita LED run on?

The RS 2400e is the only current Gavita LED offered in a 120 to 277 volt version, and the RS 1900e and CT 2000e are 208 to 480 volt fixtures. That split decides more purchases than the spectrum does, because rewiring a room costs more than the fixtures.

Current is where voltage shows up. Ten RS 2400e fixtures at 120 volts draw 66.7 amps, and the same ten at 277 volts draw 28.9 amps. On the RS 1900e, ten fixtures at 480 volts draw 13.5 amps. Higher voltage means fewer circuits and smaller panels, which is why large flower rooms usually justify 277 or 480 volt lighting.

Power cords are sold separately, so count them in the order:

  • HGC906147: 120 volt cord.
  • HGC906148: 208 to 240 volt cord.
  • HGC906458: 277 to 400 volt cord.
  • HGC906182: 277 volt twist lock cord.

The RS 1900e sell sheet lists the 208 to 240, 277 to 400 and twist lock cords, but not the 120 volt cord, which fits its 208 to 480 volt rating.

Which Gavita controller works with which fixture?

The Gavita Master Controller EL3, part HGC906174, dims the RS 2400e and RS 1900e down to 10 percent through an RJ 8P6C control connector. It is sold separately. Fixtures daisy chain to the controller, with a T splitter (HGC906708) to branch runs.

The EL3 does more than dim. According to the Hawthorne release on the RS 2400e, it adds per fixture power metering and temperature sensing, and it reads Titan VPD and soil sensors over CAN bus. Per fixture metering is useful on commissioning day, since a fixture drawing low current stands out before the first crop.

Older fixtures are where controller compatibility gets messy. The Pro 1700e manual lists the first generation EL1 and EL2 controllers and an E series adapter, and the CT 1930e has an embedded controller that lets one EL channel run up to 2,000 fixtures. If you are adding RS fixtures to a room of older Gavita lights, confirm with Hawthorne that one controller family can run both before you split the room across two.

Which Gavita LED fits which room?

The RS 2400e fits flower rooms that want high intensity and veg rooms that can run it dimmed, the RS 1900e fits 208 or 480 volt rooms with lighter rigging, and the CT series fits HPS rooms being converted. The Under Canopy and Clone Bar fill specific gaps.

  • High intensity flower: RS 2400e. Dimmed to 1,700 µmol/s, its efficacy rises to 3.15 µmol/J, as MMJ Daily reported at launch. That works out to about 540 watts, so one fixture model can serve veg and flower.
  • Standard flower on 208 or 480 volts: RS 1900e. It weighs 7.8 lb less than the RS 2400e, which adds up across a rack of 200 fixtures.
  • HPS conversions: the CT line. Hawthorne positioned the CT 1930e to reuse most existing HPS wiring and layouts, and the CT 2000e is the current Compact Toplight.
  • Dense canopy: Under Canopy 150W, adding 450 µmol/s to the lower canopy.
  • Propagation: Clone Bar on shelving.

Gavita does not publish a footprint for these fixtures. The RS 2400e sell sheet shows light maps at 12, 24, 36 and 48 inches but no coverage area. Do the upper bound math yourself: if all 2,400 µmol/s landed on a 4 by 4 ft area, the average would be about 1,615 µmol/m²/s, and over 5 by 5 ft about 1,033. Real numbers come in lower, so ask for a photometric layout at your mounting height and bench spacing. For how fixture spacing fits with racking and airflow, see our commercial grow room design guide.

How much heat does a room of Gavita LED fixtures add?

Each RS 2400e adds 2,724 BTU per hour at full output, per its sell sheet, because nearly all input power ends up as heat. Forty of them add about 109,000 BTU per hour, or just over 9 tons of cooling before you count people, dehumidifiers or pumps.

Use input watts times 3.412 for the other fixtures. The RS 1900e works out to about 2,218 BTU per hour at 650 watts. Its sell sheet repeats the RS 2400e's 2,724 figure, so trust the math over the sheet there. Dimming cuts heat in proportion to watts, which matters when veg and flower share one chiller plant.

Lighting heat sets the cooling and dehumidification plan, and the cannabis HVAC design guide shows how to carry it into tonnage. Our facility design team sizes lighting, HVAC and electrical together so the panel schedule and the cooling plant match the fixture count. If you're scoring an existing room, the cultivation facility assessment scorecard covers lighting alongside environment and labor.

Gavita LED FAQ

Is the Gavita RS 2400e DLC listed?

Yes. Hawthorne's 2023 launch materials describe the RS 2400e as the highest efficacy full spectrum DLC listed LED fixture at that time, at 3.0 µmol/J. If you plan to apply for a utility rebate, confirm the exact model and voltage version on the DLC list and with your utility before you order.

Can Gavita LED fixtures run in a wet grow room?

The RS 2400e and RS 1900e carry an IP66 wet rating and a maximum ambient rating of 40°C. Both sell sheets call IP66 a wet rating. The temperature limit is the one to watch. If your canopy temperature climbs toward 40°C on a failed cooling day, the fixtures are the second problem, not the first.

Who owns Gavita now?

Gavita fixtures are made for Hawthorne Hydroponics LLC, a subsidiary of The Hawthorne Gardening Company, with warranties from Gavita International B.V. Vireo Growth Inc. completed its purchase of Hawthorne from Scotts Miracle-Gro on April 8, 2026. Hawthorne had taken majority control of Gavita in 2016.

Should I replace Gavita 1700e fixtures with the RS 2400e?

Only if the energy and light gain pays for the swap. The RS 2400e produces 41 percent more light for 24 percent more input power, and it adds IP66 and EL3 dimming to 10 percent. If your 1700e fixtures still draw full current with few dark diodes, run the payback on your power rate first. Our Gavita 1700e specs and used value post walks through that math.

Send canopy area, room count, available voltage and target light level through our equipment request form, and we will quote Gavita fixtures, cords and EL3 controllers with lead time. Our Gavita grow lights page has the full model history and buyer notes.

Trevor Christensen
Trevor Christensen

Founder of Urth & Fyre. 1M+ square feet of cannabis facilities designed and optimized. Every answer on this site is his.

About Trevor →
Read next —

More from the blog