Pick an Anden dehumidifier by the water your canopy releases. At 0.5 to 2 pints per square foot of canopy per day, a 400 square foot veg room fits one A210V1, a 600 square foot flower canopy needs a 710 class unit or two 320 class units, and 1,000 square feet of flower takes one to three A710V3s.
What Anden dehumidifier models are in the current lineup?
Anden's current lineup runs from the 70 pint A70 to the 710 pint A710, split on its dehumidifier lineup page into medium capacity units (A70, A100, A130, A210V1) and high capacity units (A320, A321, A710, A711). Anden is the indoor agriculture brand of Therma-Stor LLC in Madison, Wisconsin, and our Anden grow room dehumidifiers page tracks the company and its parts. Here are the figures Anden publishes for each model:
- A70: 70 pints per day, up to 2.1 liters per kWh, MERV 11 filter, ducts with 8 inch flex. MSRP $1,800.05.
- A100: 100 pints per day, up to 2.6 liters per kWh, ducts with 10 inch flex. MSRP $2,005.53.
- A130: 130 pints per day, 310 CFM, up to 2.8 liters per kWh. MSRP $2,396.16.
- A210V1: 210 pints per day, 525 CFM, up to 2.9 liters per kWh, positive pressure drain with no trap needed. MSRP $3,377.78.
- A320V3: listed at 320 pints on the lineup page and up to 340 pints on its own product page, 830 CFM, up to 2.5 liters per kWh, 277 VAC. MSRP $5,152.93.
- A321 V1 and V3: up to 320 to 321 pints per day at 80°F and 60 percent RH, 775 CFM, MERV 13 filter.
- A710V3 and A710 V1: 710 pints per day at 80°F and 60 percent RH, 1,760 CFM at 0.0 inches, up to 3 liters per kWh, runs on an existing 30 amp breaker.
- A711 V1 and V3: up to 705 pints per day at 80°F and 60 percent RH, MERV 13 filter, integrated suspension points.
Efficiency climbs with size. The A70 removes about 2.1 liters per kWh and the A710V3 about 3, so a room served by small units pays more per pint of water pulled. That matters on a 24 hour duty cycle.
How do you size an Anden dehumidifier to a room?
You size an Anden dehumidifier to the water the canopy transpires, which Quest Climate, Anden's sister brand under Therma-Stor, puts at 0.5 to 2 pints per day for every square foot of canopy. Multiply canopy area by that range, then add units until rated capacity covers the high end for your stage and irrigation.
Some worked numbers at that baseline:
- 400 square foot veg canopy at 0.5 pints: 200 pints per day, one A210V1.
- 600 square foot flower canopy at 1 pint: 600 pints per day, one A710 class unit or two A321s.
- 1,000 square foot flower canopy: 500 to 2,000 pints per day, one to three A710V3s before margin.
- 2,500 square foot flower canopy at 1.5 pints: 3,750 pints per day, six 710 class units.
Two corrections keep that estimate honest. Anden rates the A710, A711 and A321 at 80°F and 60 percent RH, and a late flower room held at 50 percent runs drier than that, so real removal will be lower than the nameplate. And Anden's own applications engineer, Randy Lenz, says Anden sizes from room size, plant count, water feed, lighting type and the HVAC type and tonnage, not canopy alone. Feed those into Anden's sizing questionnaire or into a load calculation from our facility design team, and read our flower room sizing math for the A710V3 for a full worked case.
When should you step up from a 320 class unit to a 710 class Anden dehumidifier?
Step up to a 710 class Anden dehumidifier when the room needs more than about 640 pints a day and you can run a 30 amp circuit per unit. One A710 does the work of two 320 class units with one drain, one filter and one hanging point instead of two.
Airflow is the other reason. The A710V3 moves 1,760 CFM against 775 CFM for the A321, so a single large unit pushes dry air further across a long canopy. The tradeoff is weight and redundancy. The A710 V1 cabinet weighs 360 lb at about 45 by 34 by 32 inches, and if one of two units fails you lose half your capacity instead of a third or a quarter.
Quest's grow room guidance recommends a mix of large and small units. That is how we would lay out a flower room: 710 class units for the base load, plus one smaller unit that covers the gap in late flower and carries the room if a big unit goes down. Our cannabis HVAC design guide covers how that dehumidifier count sits beside cooling tonnage and reheat.
Match voltage before you pick a model
- V3 models (A710V3, A711 V3, A321 V3, A320V3): 277 VAC.
- V1 models (A710 V1, A711 V1, A321 V1): 208 to 240 VAC on the A710 V1, 208 to 230 VAC on the A711 and A321. The A710 V1 draws 22.3 amps at 240 VAC.
If your fixtures already run on 277 VAC, check whether the panel schedule has room for V3 dehumidifier circuits before you default to V1.
What changed with the Anden A321 and A711?
Anden announced the A321 and A711 on October 23, 2026, as next generation versions of its 320 and 710 class units. Per the A321 and A711 launch post, both use MERV 13 filters, both come in V1 (208 to 230 VAC) and V3 (277 VAC), and both have integrated suspension points, so a separate hang kit is no longer needed.
Anden also credits a Multi Coil Refrigeration Recovery design with a wider dew point operating range. The warranty is the part to read closely. The A321 and A711 carry a 3 year limited warranty, one year full plus two years of replacement parts. Anden lists 5 years on the A710V3, and that gap is real money.
It matters even more on a secondhand unit, which is why our used Anden dehumidifier checks start with the serial number.
The A711 is rated at up to 705 pints per day, slightly under the A710V3's 710. For a new room, we would compare the two on circuit voltage, filter cost and the warranty, not on the 5 pint difference.
Which Anden humidifiers and controls go with the dehumidifiers?
Anden pairs its dehumidifiers with two steam humidifiers and two humidity controls, because clone and veg rooms often need moisture added instead of removed. Quest Climate publishes targets of 65 to 70 percent RH for clones and seedlings, 60 to 70 percent for veg and 40 to 60 percent for flower.
- AS150 steam humidifier: 1,200 pints per day, for large veg rooms and mother rooms.
- AS35FP steam humidifier: 277 pints per day with a built in fan pack.
- A77 control: MSRP $126.80, 5 year warranty. Anden lists it as compatible with the A70, A100, A130, A210V1, A320V1, A320V3, A710V1 and A710V3.
- A65 control: Anden's humidifier control.
The A77 ships with the A710V3 and reads RH at canopy height, which is where the number matters. A wall sensor at eye level can read a different number than the leaf zone in a dense flower room.
Anden Dehumidifier FAQ
How many square feet of canopy does one A710V3 cover?
At 710 pints per day and Quest's 0.5 to 2 pints per square foot baseline, one A710V3 covers roughly 355 to 1,420 square feet of canopy. Heavy irrigation puts you near the 355 square foot end. Count on a lower real rate than the 80°F and 60 percent RH rating, and add one unit of margin.
What is the difference between the A320 and the A321?
The A321 is the newer 320 class unit, announced October 23, 2026. It moves to a MERV 13 filter, adds integrated suspension points and comes in both V1 and V3 voltages. Anden lists the A321 at 775 CFM and the A320V3 at 830 CFM. The A320V3 carries a 5 year warranty; the A321 carries a 3 year limited warranty.
Does an Anden dehumidifier need a condensate pump?
It depends on the model and the drain route. The A210V1 uses a positive pressure drain and needs no trap. The A710 drains through a 3/4 inch FNPT connection that needs a trap, and Anden includes a P trap in the fittings. If no floor drain sits below the unit, plan a pump or a gravity line before you hang it.
Can Anden dehumidifiers be ducted outside the grow room?
Yes. Anden builds the A710V3 for suspended, freestanding or inlet and outlet ducted installs, and the ducted unit can sit in a separate room. The A321 and A711 also install ducted outside the room. Ducting keeps service traffic and the unit's noise out of the canopy, at the cost of a duct kit and some static pressure.
Urth & Fyre recently sold a new 2024 Anden A710V3 listed at $6,500, and it is no longer available. To source another, send your canopy area, room stage and panel voltage through the equipment request form.
